Specialist acoustic barriers / Cheshire, Manchester & North West

Acoustic fencing. Performance starts with the specification.

The barrier is one part of the solution. The details around it matter just as much.

Strike Fencing installs specialist acoustic barriers for commercial, industrial and infrastructure sites. We bring practical product knowledge and installation experience to packages where performance, access and site conditions all need careful consideration.

Strike Fencing acoustic barrier installation at the Skelmersdale battery energy storage facility

Real Strike project: Skelmersdale Battery Energy Storage System

Energy infrastructure

Industrial sites

Commercial developments

Noise-sensitive boundaries

Discuss your project / Strike Fencing

Have a project? Talk to Strike.

Got an acoustic barrier specification or project drawings? Send us the key details and we will review the installation requirements.

Prefer to speak to us?

01606 513717

Or email us directly:

hello@strikefencing.co.uk

Quick project enquiry

Tell us what you need

Only three contact fields are required.

We'll use your details to respond to your enquiry. Submitting this form does not confirm a quotation, site survey or programme commitment.

01 / A more considered approach

Noise control requires more than a fence.

Acoustic barriers can be important elements of a wider noise mitigation strategy. Their effectiveness depends on the sound source, the location of the barrier, the route sound takes and the people or buildings being protected.

We consider how the specified system will actually be installed, from changing ground levels and supporting posts to access gates and the treatment of junctions. Those details need to support the acoustic design, not work against it.

We do not substitute installation experience for an independent acoustic assessment. Sound modelling, site noise targets and formal acoustic design responsibility should be defined by the project team and a suitably qualified specialist.

02 / Applications

Specified for the site. Planned for the conditions.

Different locations call for different considerations. The intended noise mitigation, ground conditions, layout and operational requirements should all inform the barrier package.

APPLICATION 01

Energy & infrastructure

Acoustic barriers for equipment and operational sites where nearby noise-sensitive locations are a design consideration.

APPLICATION 02

Industrial & logistics

Boundary noise barriers where plant, vehicle movements and neighbouring uses need to be considered in the wider project design.

APPLICATION 03

Commercial developments

Noise control measures that must coordinate with access arrangements, external finishes, landscaping and neighbouring properties.

APPLICATION 04

Specialist enclosures

Acoustic screening and gates within defined areas where sound transmission, site operation and maintenance access all matter.

03 / Project evidence

Skelmersdale. A demanding environment.

View the full case study
Acoustic fencing installed by Strike Fencing at Skelmersdale Battery Energy Storage System

Actual completed work at Skelmersdale

CLIENT

G2 Energy

Strike installed the specified Jacksons Jakoustic Reflective acoustic fencing on a battery energy storage project. Our input included assistance with product selection and materials sourcing.

THE SCOPE

378 linear metres of 3m high acoustic fencing, together with two sets of double-leaf vehicle access gates.

THE CONDITIONS

Winter weather and muddy ground complicated access and installation. Work also had to be planned around live battery equipment and nearby power lines.

THE DELIVERY

The installation was completed ahead of the facility becoming fully operational, with the logistical and operational constraints addressed as part of the works.

378m

Installed acoustic fencing

3m

Barrier height

2

Sets of double-leaf access gates

04 / Understanding performance

A laboratory rating is not a site prediction.

The published test data matters, but it must be interpreted correctly. A manufacturer may demonstrate how a barrier performs in a controlled test without promising that the same decibel reduction will be experienced by a neighbour.

Skelmersdale specified system

Jacksons Jakoustic Reflective

B3

BS EN 1793-2:1998 laboratory classification

28 dB

Published laboratory sound reduction

25 kg/m²

Published superficial mass

What those figures actually mean

The figures above describe the specified barrier's published laboratory characteristics. They do not show the decibel reduction measured at a receptor on the Skelmersdale site, and they should not be presented as such.

Barrier position, height, the noise source, ground and surrounding structures influence how much noise reaches a particular location. Any required site noise level must be assessed by the acoustic designer.

Reflective or absorptive?

A reflective barrier resists sound passing through it. An absorptive version also provides treatment to reduce sound reflected towards the source. Selection depends on the wider acoustic design and required performance.

Read Jacksons' technical information

Manufacturer figures are shown for the Jakoustic Reflective system recorded on this project, not as a generic performance claim for acoustic fencing. Confirm current test evidence, exact system details and project-specific requirements before specification.

05 / Details that matter

Acoustic effectiveness depends on the whole installation.

Material alone is not the full answer. The finished fence needs to follow the specified design and make practical sense on site.

CHECK 01

A tested product is not a site guarantee

Laboratory sound reduction is measured under controlled conditions. Actual sound levels at a nearby property depend on the source, geometry, distance, height, ground and routes around the barrier.

CHECK 02

Continuity matters

Gaps beneath panels, at post interfaces and around gates can undermine a barrier's effectiveness. Installation details need to follow the specified system.

CHECK 03

Position and height matter

A barrier's location relative to the noise source and receiver can be as important as its construction. The acoustic design should establish these requirements before installation.

CHECK 04

Site conditions still determine buildability

Foundations, levels, wind loads, access, services and safe construction methods must be resolved alongside the acoustic specification.

06 / Working with Strike

From specification to practical delivery.

We review the fencing package alongside the site information so that installation requirements are considered early. The acoustic design and any formal responsibility for it remain with the agreed project specialists.

Discuss a tender

01 / DELIVERY

Review the acoustic specification

Check the system, layout, relevant drawings and any acoustic consultant's recommendations. Clarify what evidence and approvals are required.

02 / DELIVERY

Confirm geometry and fixing

Review finished levels, barrier height, foundations, post arrangement, changes in level and interfaces with existing structures.

03 / DELIVERY

Coordinate gates and openings

Consider access requirements and how the specified acoustic treatment continues through entrances and other interruptions.

04 / DELIVERY

Plan the site installation

Account for deliveries, ground conditions, lifting, operational equipment, electrical exclusion zones and sequencing with other contractors.

07 / Photographs from site

Built in the conditions we actually faced.

These are real photographs from the Skelmersdale battery storage installation. Our work included planning around difficult winter ground conditions and neighbouring operational equipment.

Explore the project gallery
Details of Strike's acoustic fencing at SkelmersdaleAcoustic fencing installed on the Skelmersdale battery energy storage site

08 / Common questions

The right questions, answered clearly.

Technical and commercial points worth resolving before the product is ordered and the installation is programmed.

01Does a barrier with a 28 dB laboratory rating reduce noise at a property by 28 dB?

No. The 28 dB figure for the specified Jakoustic Reflective product is a laboratory sound reduction rating under the cited test. It is not a prediction or guarantee of sound reduction at a particular receiver. The site's acoustic consultant should assess the expected effect of the full barrier layout.

02What is the difference between reflective and absorptive acoustic fencing?

Reflective barriers primarily resist the transmission of sound through the barrier. Absorptive systems include sound-absorbing construction to reduce the sound reflected back towards the source. The right solution depends on the acoustic design, not solely on which product has the larger published number.

03Can acoustic fencing include vehicle access gates?

Yes, where a suitable gate system is specified. Gates and their interfaces are important because openings and gaps can compromise performance. Strike's Skelmersdale package included two sets of double-leaf vehicle access gates.

04Can Strike undertake acoustic design or guarantee noise levels?

We can contribute product and installation knowledge and deliver an agreed acoustic fencing package. Formal acoustic modelling, receiver-level predictions and any required performance guarantee should be established with a suitably qualified acoustic consultant and set out expressly in the contract.

05What should be included in an acoustic fencing enquiry?

Send the site location, drawings, proposed barrier lengths and heights, specified product, acoustic report if available, gate requirements, ground information, access restrictions and programme. We can then identify any missing information needed for a meaningful quotation.

06Have you installed acoustic barriers in energy infrastructure settings?

Yes. At the Skelmersdale battery energy storage project, Strike installed 378 linear metres of 3m high Jacksons acoustic fencing, together with two sets of double-leaf vehicle access gates, while managing difficult winter ground conditions and operational site interfaces.

09 / Your project

Need a specialist acoustic fencing contractor?

Send us the acoustic specification, site layout, proposed barrier lengths and heights, access requirements and programme if available. We can review the package and consider the next step.

Explore all services