Energy & infrastructure
Acoustic barriers for equipment and operational sites where nearby noise-sensitive locations are a design consideration.
Specialist acoustic barriers / Cheshire, Manchester & North West
The barrier is one part of the solution. The details around it matter just as much.
Strike Fencing installs specialist acoustic barriers for commercial, industrial and infrastructure sites. We bring practical product knowledge and installation experience to packages where performance, access and site conditions all need careful consideration.

Real Strike project: Skelmersdale Battery Energy Storage System
Energy infrastructure
Industrial sites
Commercial developments
Noise-sensitive boundaries
Discuss your project / Strike Fencing
Got an acoustic barrier specification or project drawings? Send us the key details and we will review the installation requirements.
01 / A more considered approach
Acoustic barriers can be important elements of a wider noise mitigation strategy. Their effectiveness depends on the sound source, the location of the barrier, the route sound takes and the people or buildings being protected.
We consider how the specified system will actually be installed, from changing ground levels and supporting posts to access gates and the treatment of junctions. Those details need to support the acoustic design, not work against it.
We do not substitute installation experience for an independent acoustic assessment. Sound modelling, site noise targets and formal acoustic design responsibility should be defined by the project team and a suitably qualified specialist.
02 / Applications
Different locations call for different considerations. The intended noise mitigation, ground conditions, layout and operational requirements should all inform the barrier package.
Acoustic barriers for equipment and operational sites where nearby noise-sensitive locations are a design consideration.
Boundary noise barriers where plant, vehicle movements and neighbouring uses need to be considered in the wider project design.
Noise control measures that must coordinate with access arrangements, external finishes, landscaping and neighbouring properties.
Acoustic screening and gates within defined areas where sound transmission, site operation and maintenance access all matter.
03 / Project evidence

Actual completed work at Skelmersdale
CLIENT
G2 Energy
Strike installed the specified Jacksons Jakoustic Reflective acoustic fencing on a battery energy storage project. Our input included assistance with product selection and materials sourcing.
THE SCOPE
378 linear metres of 3m high acoustic fencing, together with two sets of double-leaf vehicle access gates.
THE CONDITIONS
Winter weather and muddy ground complicated access and installation. Work also had to be planned around live battery equipment and nearby power lines.
THE DELIVERY
The installation was completed ahead of the facility becoming fully operational, with the logistical and operational constraints addressed as part of the works.
Installed acoustic fencing
Barrier height
Sets of double-leaf access gates
04 / Understanding performance
The published test data matters, but it must be interpreted correctly. A manufacturer may demonstrate how a barrier performs in a controlled test without promising that the same decibel reduction will be experienced by a neighbour.
Skelmersdale specified system
B3
BS EN 1793-2:1998 laboratory classification
28 dB
Published laboratory sound reduction
25 kg/m²
Published superficial mass
What those figures actually mean
The figures above describe the specified barrier's published laboratory characteristics. They do not show the decibel reduction measured at a receptor on the Skelmersdale site, and they should not be presented as such.
Barrier position, height, the noise source, ground and surrounding structures influence how much noise reaches a particular location. Any required site noise level must be assessed by the acoustic designer.
Reflective or absorptive?
A reflective barrier resists sound passing through it. An absorptive version also provides treatment to reduce sound reflected towards the source. Selection depends on the wider acoustic design and required performance.
Manufacturer figures are shown for the Jakoustic Reflective system recorded on this project, not as a generic performance claim for acoustic fencing. Confirm current test evidence, exact system details and project-specific requirements before specification.
05 / Details that matter
Material alone is not the full answer. The finished fence needs to follow the specified design and make practical sense on site.
Laboratory sound reduction is measured under controlled conditions. Actual sound levels at a nearby property depend on the source, geometry, distance, height, ground and routes around the barrier.
Gaps beneath panels, at post interfaces and around gates can undermine a barrier's effectiveness. Installation details need to follow the specified system.
A barrier's location relative to the noise source and receiver can be as important as its construction. The acoustic design should establish these requirements before installation.
Foundations, levels, wind loads, access, services and safe construction methods must be resolved alongside the acoustic specification.
06 / Working with Strike
We review the fencing package alongside the site information so that installation requirements are considered early. The acoustic design and any formal responsibility for it remain with the agreed project specialists.
Discuss a tender01 / DELIVERY
Check the system, layout, relevant drawings and any acoustic consultant's recommendations. Clarify what evidence and approvals are required.
02 / DELIVERY
Review finished levels, barrier height, foundations, post arrangement, changes in level and interfaces with existing structures.
03 / DELIVERY
Consider access requirements and how the specified acoustic treatment continues through entrances and other interruptions.
04 / DELIVERY
Account for deliveries, ground conditions, lifting, operational equipment, electrical exclusion zones and sequencing with other contractors.
07 / Photographs from site
These are real photographs from the Skelmersdale battery storage installation. Our work included planning around difficult winter ground conditions and neighbouring operational equipment.
Explore the project gallery

08 / Common questions
Technical and commercial points worth resolving before the product is ordered and the installation is programmed.
No. The 28 dB figure for the specified Jakoustic Reflective product is a laboratory sound reduction rating under the cited test. It is not a prediction or guarantee of sound reduction at a particular receiver. The site's acoustic consultant should assess the expected effect of the full barrier layout.
Reflective barriers primarily resist the transmission of sound through the barrier. Absorptive systems include sound-absorbing construction to reduce the sound reflected back towards the source. The right solution depends on the acoustic design, not solely on which product has the larger published number.
Yes, where a suitable gate system is specified. Gates and their interfaces are important because openings and gaps can compromise performance. Strike's Skelmersdale package included two sets of double-leaf vehicle access gates.
We can contribute product and installation knowledge and deliver an agreed acoustic fencing package. Formal acoustic modelling, receiver-level predictions and any required performance guarantee should be established with a suitably qualified acoustic consultant and set out expressly in the contract.
Send the site location, drawings, proposed barrier lengths and heights, specified product, acoustic report if available, gate requirements, ground information, access restrictions and programme. We can then identify any missing information needed for a meaningful quotation.
Yes. At the Skelmersdale battery energy storage project, Strike installed 378 linear metres of 3m high Jacksons acoustic fencing, together with two sets of double-leaf vehicle access gates, while managing difficult winter ground conditions and operational site interfaces.
09 / Your project
Send us the acoustic specification, site layout, proposed barrier lengths and heights, access requirements and programme if available. We can review the package and consider the next step.
Explore all services